5-1. TROUBLE SHOOTING GUIDE
Problem Cause Correction
POWER switch ON but fryer Open circuit Plug fryer in
completely inoperative
Check breaker or fuse at supply
box
Shortening will not Open high limit Reset high limit per
heat but lights are on. circuit High Limit Temperature
Error message “E10” Control Section
Drain valve open Turn drain valve handle to
Error message “E15” closed position
Foaming or boiling Water in shortening At end of Cook Cycle, drain
over of shortening shortening and clean
Improper or bad Use recommended shortening
shortening
Improper filtering Refer to the procedure covering
filtering the shortening
Improper rinsing after Clean and rinse the frypot, then
cleaning the fryer dry thoroughly
Shortening will not Drain valve clogged Open valve, force cleaning
drain from frypot with crumbs brush through drain
Filter switch on, Motor thermal Reset thermal switch per section
motor does not run protector tripped on Filter Pump Motor
Protector Manual Reset
More detailed troubleshooting information is available in the Technical Manual, available at
www.hennypenny.com, or 1-800-417-8405 or 1-937-456-8405.
903 5-1
SECTION 5. TROUBLESHOOTING
Page view 0
1 2 3

Summary of Contents

Page 1 - SECTION 5. TROUBLESHOOTING

Model OFE/OFG/OEA/OGA-341, 342 5-1. TROUBLE SHOOTING GUIDE Problem Cause Correction POWER switch ON but fryer • Open circuit

Page 2

Model OFE/OFG/OEA/OGA-341, 342 5-2. ERROR CODES In the event of a control system failure, the digital display will show an "E

Page 3 - 908 5-3

Model OFE/OFG/OEA/OGA-341, 342 5-2. ERROR CODES (Continued) DISPLAY CAUSE PANEL BOARD CORRECTION “E-20 A”

Comments to this Manuals

No comments