Henny Penny HDS-200 User Manual

Browse online or download User Manual for Unknown Henny Penny HDS-200. Henny Penny HDS-200 User's Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 1
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Model HDS-200/300
4-1. TROUBLESHOOTING GUIDE
Product not Cold well or hot well not Check plugs under table-top
holding plugged-in on french fry end of HDS-300
temperature
Product held too long Only hold product for
recommended times
Cold well setting turned Turn control setting to about 6
Compressor overheated Clean condenser coil
Product not a proper Be sure product is at proper
temperature when placed temperature
into unit
Defective fuse for refrigeration Replace 15 amp fuse
unit
Refrigeration unit runs Frost build-up Defrost unit
constantly
Condensor coil dirty Clean condenser coil
Power switch on but Open Circuit Plug unit in
no power to unit
Check circuit breaker
Check 15 amp fuses
Check cord and plug
for loose connection
Not all lights Faulty light bulbs Replace with new bulb,
on per Light Bulb Replacement
Section
Lights will Defective fuse Replace 15 amp fuse
not turn on
PROBLEM CAUSE CORRECTION
SECTION 4. TROUBLESHOOTING
4-1 605
Page view 0
1

Summary of Contents

Page 1 - SECTION 4. TROUBLESHOOTING

Model HDS-200/3004-1. TROUBLESHOOTING GUIDEProduct not • Cold well or hot well not • Check plugs under table-topholding plugged-in on french fry end

Comments to this Manuals

No comments