3-6. OPERATION AND Setting Control to the Correct Number of Drawers
PROGRAMMING
(Continued) The different models, MP-941, 942, 943, and 944, all use
the same control board. The boards are programmed at
the factory for the correct unit. But, should the unit show
“E06” or some drawers will not heat, the board may not
be programmed for the appropriate unit.
The LED flashes at a fast rate for the drawer(s) not
programmed correctly.
To check the drawer programming, turn the unit off, then
back on. The display will flash the number of drawers
the unit is programmed for. If the unit is not programmed
correctly, follow these steps:
1. Turn the power switch off, then press and hold the
SET button and the drawer button, which corresponds
to the number of drawers that the unit has, and turn
unit back on, ex: MP-944=SET and number 4 button.
2. Release the buttons, and now the unit should be set
up for use.
Pressing and holding the drawer button shows the
temperature of that drawer. If no temperature is
displayed, the unit may need to be programmed by
the above steps.
3-7. ERROR CODES
DISPLAY CAUSE PANEL BOARD CORRECTION
E-4” Control board Turn switch to OFF position, then turn switch back to
overheating ON; if display shows “E-4,” the control board is
getting too hot; make sure unit is not overheating
“E-6” Faulty temperature Check to see if unit is set to the correct number of
probe drawers, ex: MP-942=2 drawers (see programming
instructions)
“E-41” Memory scrambled Press and release the UP and DOWN buttons to
initialize the program; if “E-41” persists replace the
control board
“Hi” Unit overheating; Have relay or control board replaced
faulty relay or
control board
3-6 203