Henny Penny OEA User Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 22
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
Model OFE/OFG/OEA/OGA-341, 342
3-9. FILTERING OF 6. Rinse the frypot as follows:
SHORTENING a. Close the drain valve.
(Continued) b. Position return line over empty frypot. Figure 3-8.
c. Move the pump switch to the pump position.
d. Fill the frypot 1/3 full, then turn off pump.
e. Wash down and scrub the sides of the frypot
with the brushes.
f. After the sides and bottom are cleaned, open the
drain valve.
7. Close drain valve and pump all of the shortening out of
the filter drain pan and back into the frypot.
Figure 3-8
IF SHORTENING FLOW IS SLOW FROM THE
FAUCET, IT’S POSSIBLE THAT THE FILTER
CONNECTION AT THE UNION ON THE
FILTER TUBE IS NOT TIGHTENED
PROPERLY. IF SO, TURN OFF THE PUMP AND
WEAR ROTECTIVE GLOVES OR CLOTH
WHEN TIGHTENING THE UNION. THIS
UNION WILL BE HOT. SEVERE BURNS
COULD RESULT.
8. When the pump is pumping air only, move the pump
switch from on to off.
9. Check the level of the shortening in the frypot. Add
fresh shortening if necessary, until it reaches the top
level indicator line on the rear wall of the frypot.
406 3-15
Page view 14
1 2 ... 10 11 12 13 14 15 16 17 18 19 20 21 22

Comments to this Manuals

No comments