Henny Penny MP-944 User Manual Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
Model MP-941/942/943/944
3-5. CLEANING (Continued) 5. Clean the interior of the cabinet thoroughly with a
cloth and soapy water.
Do not use steel wool, other abrasive cleaners or
cleaners/sanitizers containing chlorine, bromine,
iodine or ammonia chemicals, as these will
deteriorate the stainless steel material and shorten
the life of the unit.
Do not spray the unit with water, such as, with
a garden hose. Failure to follow this caution could
cause component failure.
6. Wipe down the exterior of the cabinet with a damp
cloth. Avoid getting water in the area of the control
panel.
7. Replace the drawers.
8. If the unit is to be left off, leave the drawers open
two or three inches.
3-6. OPERATION AND
Unit Operation
PROGRAMMING
1. Turn POWER switch to the ON position.
2. The display will show the time of day, or “ON”.
Press and hold any of the drawer buttons to view the
actual temperature of the drawer.
Time of Day Programming
Press and hold the SET button while using the UP
and DOWN buttons to set the desired time. When
the SET button is released the time will be saved.
Temperature Setpoint Programming
1. Press and hold the appropriate drawer button for 6
seconds. The actual temperature will be shown first
followed by the flashing setpoint temperature.
3-4 203
Page view 12
1 2 ... 8 9 10 11 12 13 14 15 16 17 18

Comments to this Manuals

No comments