7-2. ERROR CODES
DISPLAY CAUSE CORRECTION
“E-21” Slow heat recovery Have a certified service technician check the fryer for correct
voltage to the unit; have the contactors and heating element
checked; have unit checked for loose or burnt wires
“E-22” “NO HEAT” Elements not Check power cord and heat circuit
“CHECK PWR heating
CORD AND
BREAKER”
“E-31” Elements are up Lower elements completely back into the vat
“E-41”, “E-46” Programming Turn switch to OFF, then back to ON; if display shows any
failure of these error codes, have the controls re-initialized; if error code
persists, have the control board replaced
“E-47” Analog converter Turn switch to OFF, then back to ON; if “E-47” persists,
chip or 12 volt have the I/O board, or the PC board replaced; if speaker
supply failure tones are quiet, probably I/O board failure; have the I/O board
replaced
“E-48” Input system Turn switch to OFF, then back to ON; have controlPC board
error replaced if “E-48” persists
“E-54C” Temperature input Turn switch to OFF, then back to ON; have control PC board
error replaced if “E-54C” persists
“E-60” AIF PC board not Press power button to vat off and back on again if “E-60”
communicating with persists, have the connector between the PC boards checked;
control PC board replace AIF PC board or control PC board if necessary