Model 691
2-7. GAS PIPING The fryer must be isolated from the gas supply piping
(Continued) system by closing its manual shutoff valve during any
pressure testing of the gas supply piping system at
test pressures equal to or less than 1/2 psig
(3.45 kPa) (34.5 mbar).
A standard 3/4 inch, black steel pipe and malleable
fittings should be used for gas service connections.
Do not use cast iron fittings.
Although 3/4 inch size pipe is recommended, piping
should be of adequate size and installed to provide a
supply of gas sufficient to meet the maximum demand
without undue loss of pressure between the meter and
the fryer. The pressure loss in the piping system
should not exceed 0.3 inch water column (0.747 mbar).
Provisions should be made for moving the fryer for cleaning
and servicing. This may be accomplished by:
1. Installing a manual gas shutoff valve and disconnect
union, or
2. Installing a heavy-duty design (minimum 3/4”) A.G.A. certi-
fied connector which complies with standard connectors for
moveable gas appliances. ANSI Z21.69 (the latest edition)
or CAN l, 6. l0M88. Also, a quick-disconnect coupling
which complies with the Standard for Quick-Disconnect De-
vices for use with Gas Fuel, ANSI Z21.41 (the latest
edition) or CAN 1 6.9M79. Also, adequate means must
be provided to limit the movement of the fryer without
depending on the connector and any quick-disconnect
device or its associated piping to limit the fryer movement.
3. See the illustration on the following page for the
proper connections of the flexible gas line and cable
restraint.
The cable restraint limits the distance the fryer can be pulled
from the wall. For cleaning and servicing the fryer, the cable
must be unsnapped from the unit and the flexible gas line
disconnected. This allows better access to all sides of the
fryer. The gas line and cable restraint must be reconnected
once the cleaning or servicing is complete.
1102 2-7